Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

FERROFLUIDIC SEAL

Solid shaft sealing flange of water-cooled magnetic transmission device

Magnetic liquid is a kind of suspended colloid with solid and liquid mixed, which is formed by adding magnetic nanoparticles into the carrier liquid and dispersing evenly into the carrier fluid by use of a surface-ctive dispersant. Magnetic liquid both has the fluidity of liquid and magnetism, and its sealing technology is realized by taking advantage of the response characteristics of magnetic liquid to the magnetic field. When we inject this magnetic liquid into the gap of the magnetic circuit consisting of permanent magnets with high performance, and pole shoes with good magnetic permeability and axis, magnetic fluid in the gap will form some "O" circles of liquid under the the action of magnetic field. Its quantity and design move slightly in the non-uniform magnetic field, forming magnetic force against the differential pressure to achieve a new equilibrium and play the role of sealing.
  • Product Description
  • FAQ
  • Related Products

Product Description

Model d D1 D2 N-Φd0 D3 L L1 L2 L3 A(W × D × L)
SF010ZP 10h7 50 70 4-Φ9 85 135 85 25 8 3x1.8x15
SF012ZP 12h7 55 75 4-Φ9 95 135 85 25 10 4x2.5x15
SF016ZP 16h7 65 85 6-Φ9 105 165 105 30 10 5x3x20
SF020ZP 20h7 70 90 6-Φ9 105 180 110 35 10 6x3.5x25
SF025ZP 25h7 80 100 6-Φ9 115 195 115 40 12 8x4x30
SF030ZP 30h7 90 110 6-Φ9 125 220 120 50 12 8x4x40
SF035ZP 35h7 100 125 6-Φ11 145 245 125 60 15 10x5x50
SF040ZP 40h7 105 130 6-Φ11 150 270 130 70 15 12x5x60
SF045ZP 45h7 110 135 8-Φ11 155 295 135 80 15 14x5.5x70
SF050ZP 50h7 120 145 8-Φ11 165 300 140 80 15 14x5.5x70

Magnetic liquid is a kind of suspended colloid with solid and liquid mixed, which is formed by adding magnetic nanoparticles into the carrier liquid and dispersing evenly into the carrier fluid by use of a surface-ctive dispersant. Magnetic liquid both has the fluidity of liquid and magnetism, and its sealing technology is realized by taking advantage of the response characteristics of magnetic liquid to the magnetic field. When we inject this magnetic liquid into the gap of the magnetic circuit consisting of permanent magnets with high performance, and pole shoes with good magnetic permeability and axis, magnetic fluid in the gap will form some "O" circles of liquid under the the action of magnetic field. Its quantity and design move slightly in the non-uniform magnetic field, forming magnetic force against the differential pressure to achieve a new equilibrium and play the role of sealing.

Leak proofs of "zero" leak: under the action of magnetic force, magnetic fluid forms an "O" circle of liquid, filling the gap between the spindle and pole shoe, seriously hindering the flow of gas, to achieve the stable dynamic and static sealing effect. Its leakage is so weak that even under the condition of 1X10-12Pa-m%/sec, an amas spectrometer can not detect it.
Stable and reliable performance, long service life: due to the base fluid of magnetic fluid being an inert, stable aliphatic organic material with low vapor pressure and low volatilization, its normal working life is generally more than five years.

High reliability, non-directional seal: when magnetic liquid seal element produces transient over-oltage breakdown under the condition of positive pressure, once the pressure is reduced to the degree that magnetic force can withstand, magnetic fluid quickly recovers the sealing effect under the action of magnetic force. The reliability of its use is quite high and both ends of magnetic fluid can be arbitrarily pressed, so there is no direction.

Low friction, low wear, low fever, low block, no pollution: because the axis rotates ni magnetic fluid, there is small friction, no fever, no block for the transmission of torque, small power loss, and no mechanical wear ni magnetic liquid itself, magnetic fluid saturation, low vapor pressure, and even in the high vacuum condition, the use of it also will not produce pollution. There are two motion forms, which si rotation type and reciprocating movement. Seal size ranges from 06 to ® osmm.

FAQ

  • Q: What industries does HQ support?

    A: We deliver customized sealing solutions to diverse industrial sectors,including:
    ·Oil and Gas
    ·Refining
    ·Chemical and Petrochemical
    ·Water and Wastewater Treatment
    ·Pharmaceutical
    ·Power Generation
    ·Marine
    Our products are designed to perform reliably in demanding environments across multiple industries.

  • Q: Do you offer custom sealing solutions?

    A: HQ Seals provides custom sealing solutions customized for your working conditions. We manufacture seals according to:
    · Technical drawings
    · Physical samples
    · Special material & performance specifications
    · Non-standard sizes
    We maintain close communication with clients to guarantee all finished products satisfy operational and environmental requirements.

  • Q: How can I choose the right mechanical seal for my use?

    A: First, identify the optimal configuration (single or double seal) according to the process fluid. Then verify operating parameters — pressure, temperature and shaft speed — to select the appropriate seal type and materials. Lastly, confirm available installation dimensions, and opt for either a component or cartridge seal subject to customer requirements and relevant standards. Seal selection is normally carried out by qualified technicians.

  • Q: What types of after-sales services does HQ provide?

    A: For mechanical seals that have been stored for a long period: we can grind the rotating and stationary rings, replace secondary sealing O-rings, conduct air tightness testing and issue the pressure test report.
    We can provide on-site installation guidance service. For failed mechanical seals, we are able to deliver failure analysis reports.

  • Q: Can mechanical seals be repaired, or must they be replaced?

    A: Yes, repairs are available. Depending on the damage condition of the mechanical seal, we classify the overhaul into Level 1, Level 2 and Level 3 repair.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Country/Region
Message
0/1000