Installation Precautions:
When using a magnetic liquid seal element for a vacuum seal, please avoid dripping acetone, ethanol, acid, alkali, water, non-vacuum oil, and other solvents into the magnetic liquid seal to avoid causing the seal to fail.
The shape and location accuracy of the internal mechanical structure in magnetic liquid sealing devices is highly emphasized.
When there is wrong with the magnetic liquid seal, please pass the information to the manufacturer in time and let the manufacturer to define and handle failure.
When magnetic liquid seal elements work for the first time, vacuum time should be longer, and rotate spindle of the magnetic liquid seal a few times before turning it on. Magnetic liquid seal with a water cooling device should first get through the cooling water to avoid seal failure caused by overheating temperature (temperature over 80 degrees Celsius).

| Model | d | D1 | D2 | N-Φd0 | D3 | L | L1 | L2 | L3 | A(W × D × L) |
| SF006WP | 6h7 | 35 | 50 | 4-Φ7 | 65 | 100 | 60 | 20 | 8 | 2x1.2x1.2 |
| SF010WP | 10h7 | 45 | 60 | 4-Φ7 | 75 | 120 | 70 | 25 | 8 | 3x1.8x15 |
| SF012WP | 12h7 | 48 | 65 | 4-Φ9 | 85 | 125 | 75 | 25 | 10 | 4x2.5x15 |
| SF016WP | 16h7 | 58 | 75 | 4-Φ9 | 95 | 145 | 85 | 30 | 10 | 5x3x20 |
| SF020WP | 20h7 | 65 | 85 | 6-Φ9 | 105 | 160 | 90 | 35 | 10 | 6x3.5x25 |
| SF025WP | 25h7 | 75 | 95 | 6-Φ9 | 115 | 185 | 105 | 40 | 12 | 8x4x30 |
| SF030WP | 30h7 | 85 | 105 | 6-Φ9 | 125 | 210 | 110 | 50 | 12 | 8x4x30 |
| SF035WP | 35h7 | 95 | 120 | 6-Φ11 | 145 | 235 | 115 | 60 | 15 | 10x5x50 |
| SF040WP | 40h7 | 100 | 125 | 6-Φ11 | 145 | 260 | 120 | 70 | 15 | 12x5x60 |
| SF045WP | 45h7 | 105 | 130 | 8-Φ11 | 155 | 285 | 125 | 80 | 15 | 14x5.5x70 |
| SF050WP | 50h7 | 115 | 140 | 8-Φ11 | 165 | 290 | 130 | 80 | 15 | 14x5.5x70 |
A: We deliver customized sealing solutions to diverse industrial sectors,including:
·Oil and Gas
·Refining
·Chemical and Petrochemical
·Water and Wastewater Treatment
·Pharmaceutical
·Power Generation
·Marine
Our products are designed to perform reliably in demanding environments across multiple industries.
A: HQ Seals provides custom sealing solutions customized for your working conditions. We manufacture seals according to:
· Technical drawings
· Physical samples
· Special material & performance specifications
· Non-standard sizes
We maintain close communication with clients to guarantee all finished products satisfy operational and environmental requirements.
A: First, identify the optimal configuration (single or double seal) according to the process fluid. Then verify operating parameters — pressure, temperature and shaft speed — to select the appropriate seal type and materials. Lastly, confirm available installation dimensions, and opt for either a component or cartridge seal subject to customer requirements and relevant standards. Seal selection is normally carried out by qualified technicians.
A: For mechanical seals that have been stored for a long period: we can grind the rotating and stationary rings, replace secondary sealing O-rings, conduct air tightness testing and issue the pressure test report.
We can provide on-site installation guidance service. For failed mechanical seals, we are able to deliver failure analysis reports.
A: Yes, repairs are available. Depending on the damage condition of the mechanical seal, we classify the overhaul into Level 1, Level 2 and Level 3 repair.